Why Choose Star Networking Services for Structured Cabling?
Passive components are where projects quietly lose money. The cable is quoted, the jacks and panels are forgotten, and the shortfall turns up on the day the installer is already on site. We quote the full passive list from the outlet count, because that is the number every other line follows from.
- Established in 1998 — 27+ years of continuous trading in Chennai, not a recent reseller
- More than 300 completed projects for IT companies, hospitals, factories, offices and retail
- Structured cabling is our origin trade, not a category we added later
- Genuine Molex, Honeywell, CommScope and D-Link product with manufacturer warranty terms
- The whole passive list quoted from the outlet count, so nothing is discovered mid-installation
- Installation, testing and certification, not supply alone
- 24×7 technical support, including emergency restoration
- Annual maintenance contracts after handover
- B2B and bulk supply with GST invoicing and volume pricing
- BOQ-based quoting for system integrators and cabling contractors
Structured Cabling Products We Supply in Chennai
Every line below follows from one number: how many outlets the site needs. Fix that first and the rest of the order calculates itself.
Cat6 UTP Cable
Boxed cable for the permanent link. Solid conductor for in-wall runs, and full-size copper rather than copper-clad aluminium — the difference shows up as voltage drop on PoE runs and heat inside bundled trays, not as bandwidth.
Cat6 Patch Cords
Factory-terminated stranded cords at both ends of every link. Buy the length you need — coiled slack behind a rack is the commonest cause of a link failing certification after passing on the day.
Information Outlets & Keystone Jacks
The outlet end of the permanent link. Cat6 jacks punch down to the solid cable and give you a socket that can be tested, traced and re-terminated — which a crimped plug on solid cable cannot.
RJ45 Connectors & Face Plates
Modular plugs for stranded patch cords, and single-module data sockets for the wall. RJ45 plugs belong on stranded cable; crimping them onto solid in-wall cable is the shortcut that fails a year later.
Network Racks
Wall-mount racks to house the switch, patch panel and recorder. Depth matters more than height on a wall rack — a 600 mm depth takes a switch with rear-facing ports and still lets the door close.
Cable Managers & PDUs
A horizontal manager between the panel and the switch is what lets someone trace a link a year later. The PDU is what stops a rack being fed from a strip on the floor — ours carry an MCB and an indicator.
Fiber Patch Cords
LC-LC and SC-SC cords for uplinks and backbone terminations, where copper runs out of distance. Connector type has to match the LIU and the transceiver at both ends — that is the detail worth confirming before ordering.
Active and Passive Components — Where the Line Falls
Active components need power and make decisions about traffic. Passive components carry the signal and never touch it. The distinction matters at quoting time because the two behave completely differently over a project's life: active kit is replaced on a refresh cycle, passive cabling stays in the walls for fifteen years.
- Active — network switches, PoE switches, routers, wireless access points, media converters, SFP transceivers
- Passive — Cat6 and Cat6A cable, information outlets, keystone jacks, face plates, patch cords, patch panels
- Passive also — racks, cable managers, PDUs, fiber cable, LIU enclosures, pigtails, adapters and couplers
- Spend carefully on passive: it is the layer that is expensive to revisit and invisible when it is right
Active & Passive Networking Components · Network switches · Networking Products Supplier in Chennai
Cabling Product Brands We Supply
We stock Molex, Honeywell, CommScope and D-Link across the copper range, with Netrack and Netfox on racks and power. Which brand suits a project usually comes down to what the site is already standardised on.
Molex
Cat6 UTP cable and patch cords. The default where a site wants one brand end to end and a warranty that covers the channel rather than the components.
Honeywell
Patch cords and face plates. Practical, widely available, and the usual choice on fit-outs where the outlet count is high and the budget is real.
CommScope
Cat6 information outlets. Specified on projects that will be certified against a channel warranty, where the jack has to come from an approved list rather than whatever is in stock.
D-Link, Netrack and Netfox
D-Link for RJ45 modules and outlets, Netrack for cable management and PDUs, Netfox for wall-mount racks. The practical middle of most Chennai fit-outs.
How a Structured Cabling Order Comes Together
Working in this order is what stops a site discovering it is forty jacks short on installation day. Every line follows from the outlet count.
- Count the outlets, and mark which will carry PoE devices — cameras, access points, IP phones
- One information outlet and one keystone jack per outlet
- One face plate per outlet position, sized for the module count at that point
- Cable: total run length across all outlets, plus 10 to 15% for routing and slack, bought by the box
- Patch panel ports to match the outlet count, with room for growth
- Two patch cords per outlet — one at the desk, one at the panel
- Rack sized from the panel, switch and any recorder, with a horizontal manager between panel and switch
- PDU with an MCB, sized for everything in the cabinet
- Fiber patch cords and LIU only where a run exceeds the copper limit
Choosing Cat6 — What Actually Differs Between Boxes
Cat6 boxes that look identical are not. The differences do not show up in a speed test on day one; they show up as failed certification, PoE voltage drop, and heat in bundled trays.
Conductor is the first thing to check. Full-size solid copper is what the standard assumes. Copper-clad aluminium is cheaper, lighter and legal to sell, but it carries less power and breaks more easily at the punch-down — and on a PoE run it is the difference between a camera that holds and one that drops at night.
- Solid conductor for permanent in-wall links; stranded only for patch cords
- Pure copper, not copper-clad aluminium — check the box, not the shelf label
- Conductor gauge: 23 AWG is standard Cat6, 24 AWG is thinner and drops more voltage on PoE
- Box length and whether the pull-out is clean — a tangled box costs installation time
- Jacket rating for the route: indoor, riser or outdoor
- 90 m permanent link, 100 m channel including patch cords — measure before you buy
Cat6 Cable Supplier in Chennai
Structured Cabling Product Prices in Chennai
Passive components are quoted per unit and the quantities are large, so the per-unit price matters less than getting the count right. A site that under-orders jacks by ten pays far more in a second delivery than it saved on the unit rate.
As a reference from the products on this page: RJ45 connector modules from around Rs 7, Cat6 information outlets around Rs 150 to Rs 168, face plates around Rs 75, Cat6 patch cords from around Rs 160 for 1 m and Rs 355 for 2 m, a 6-socket PDU with MCB around Rs 755, a 2U cable manager around Rs 900, a 9U wall-mount rack around Rs 4,386, and a box of Molex Cat6 UTP cable around Rs 9,200.
- Quantity — passive lines are volume items and price per unit moves with the order
- Brand, and whether the project needs an approved-list jack for a channel warranty
- Conductor: pure copper versus copper-clad aluminium
- Cat6 versus Cat6A, which changes cable, jack and panel together
- Rack size, depth and whether it is wall-mount or floor-standing
- Whether installation, termination and certification are in scope
Request current pricing
Cabling Products for Different Projects
Office Fit-Outs
High outlet counts, one or two modules per position, and a rack per floor. The number that drives everything is desks multiplied by outlets per desk, and it is almost always higher than the first estimate.
CCTV Installations
One run per camera, terminated at a patch panel rather than crimped direct, so a camera can be swapped without re-pulling cable. Pure copper matters here more than anywhere because every run carries power.
Server Rooms
Patch panels, horizontal managers, PDUs and short patch cords in disciplined lengths. This is where cable management stops being tidiness and becomes the reason a fault takes ten minutes instead of an afternoon.
Factories and Warehouses
Long runs against the 90-metre limit, more jacket rating than jack count, and fiber where copper runs out. Plan switch positions from the cable limit rather than from where the office happens to be.
Schools and Campuses
Copper inside blocks and fiber between them. Outlet counts are high in labs and low everywhere else, so quote per block rather than averaging across the campus.
Apartments and Commercial Buildings
Lockable racks with clear ownership, because the cabling will be extended by somebody else later. Label and document at handover or the next contractor starts by guessing.
Structured Cabling Installation in Chennai
We install as well as supply. Cabling, fiber splicing, testing and certification have been the core of the business since 1998, so a passive order here does not stop at delivery.
- Route survey and cable pulling, with runs kept inside the 90-metre permanent-link limit
- Outlet and patch panel termination, punched down rather than crimped
- Labelling at both ends, to a scheme that survives the next contractor
- Rack build, patching and cable management
- Link testing and certification against the cable standard
- Fiber splicing and termination where the backbone needs it
- Handover with the as-built cable schedule and port map
Cabling Products for System Integrators & Contractors
A large share of what we supply goes to cabling contractors and integrators doing the installation themselves. Send the BOQ as it stands — we quote line by line against the model numbers in it, flag anything discontinued with an equivalent, and confirm what is in stock against what needs an indent.
- BOQ-based procurement, quoted line by line
- Bulk quantities with volume pricing and GST invoicing
- Model-specific matching, including approved-list jacks where a channel warranty requires them
- Project pricing held for the duration rather than quoted per despatch
- Copper, fiber, racks, power and active kit on one order
- Phased despatch against a project schedule
Structured Cabling Supplier in Chennai — Areas We Serve
Star Networking Services is based in Choolaimedu, Chennai and supports networking, structured cabling and CCTV requirements for customers and projects across Chennai. Contact our team to discuss your site location and project requirements.
Request a Structured Cabling Quote in Chennai
Send the outlet count, the longest run, how many outlets carry PoE devices, and whether the project needs certification. That is enough for us to come back with the full passive list — cable, jacks, plates, panels, cords, rack and power — as one specification rather than a cable price.
Call or WhatsApp +91 98410 12427, or email george@starnetworkindia.com.
Contact Star Networking Services
Star Networking Services supplies the passive half of a network in Chennai — Cat6 UTP cable, patch cords, information outlets and keystone jacks, RJ45 connectors, face plates, patch panels, wall-mount racks, cable managers, PDUs and fiber patch cords from Molex, Honeywell, CommScope, D-Link, Netrack and Netfox. Established in 1998, we bring 27+ years of experience in structured cabling and networking, and we install, test and certify what we supply, with 24×7 technical support and annual maintenance contracts behind it. Structured cabling is the one layer nobody re-does cheaply — it goes in the walls first and comes out last, which is why we quote the whole passive list rather than the cable alone.
Buying guides
Network Kits buying guides
Frequently Asked Questions
Which is the best structured cabling accessories supplier in Chennai?
Judge it on whether the supplier quotes the full passive list from your outlet count rather than just the cable, and whether they can test and certify what they supply. Star Networking Services has supplied and installed structured cabling in Chennai since 1998, 27+ years, across more than 300 projects, stocking Molex, Honeywell, CommScope and D-Link with bulk pricing, GST invoicing, AMC and 24×7 technical support.
Do you supply Cat6 cables and connectors in bulk for Chennai businesses?
Yes. We supply Cat6 UTP cable, patch cords, information outlets, keystone jacks, face plates, patch panels and RJ45 connectors in bulk with GST invoicing for structured cabling contractors and businesses across Chennai. Send the outlet count or the BOQ and we will quote line by line.
What is the difference between active and passive networking components?
Active components need power and make decisions about traffic — switches, routers, access points, media converters, SFP transceivers. Passive components carry the signal without touching it — cable, jacks, outlets, face plates, patch cords, panels, racks and fiber. Active kit is replaced on a refresh cycle; passive cabling stays in the walls for fifteen years, which is why it is worth specifying carefully.
How much Cat6 cable do I need for my office?
Work from the outlet count, not the floor area. Add up the route length for every outlet back to the rack, then add 10 to 15% for routing, slack and termination. Buy by the box and confirm no single permanent link exceeds 90 metres — beyond that you need a closer switch or a fiber run.
Should I use solid or stranded Cat6 cable?
Solid conductor for permanent in-wall links, punched down into jacks and patch panels. Stranded for patch cords, which flex. Crimping an RJ45 plug onto solid cable is the shortcut that passes on the day and fails a year later, so use a jack at the outlet and a factory cord at the desk.
Is copper-clad aluminium Cat6 cable acceptable?
It is cheaper and legal to sell, but it carries less power and breaks more easily at the punch-down. On a PoE run it is the difference between a camera that holds through the night and one that drops when infrared raises the draw. We supply full-size pure copper, and it is worth checking the box rather than the shelf label wherever you buy.
Do you supply network racks and cable managers?
Yes — wall-mount racks including 9U with 600 mm depth, horizontal cable management organisers, and 6-socket PDUs with a 16 A MCB and indicator. Depth matters more than height on a wall rack, since it decides whether a switch with rear-facing ports lets the door close.
Do you supply fiber patch cords?
Yes — LC to LC and SC to SC fiber patch cords, and we source OFC cable, LIU enclosures, pigtails, adapters and fiber accessories for project requirements. Connector type has to match the LIU and the transceiver at both ends, so send the models rather than just the length.
Which brands of networking products do you supply?
Molex, Honeywell, CommScope and D-Link across the copper range, with Netrack for cable management and PDUs and Netfox for wall-mount racks. Where a project needs an approved-list jack for a channel warranty, tell us at quoting time and we will match it rather than substitute.
Do you provide installation, testing and maintenance?
Yes to all three. Alongside supply we carry out cable pulling, outlet and panel termination, labelling, rack build, fiber splicing, and link testing and certification, with as-built documentation at handover. After that we offer annual maintenance contracts covering diagnostics, re-termination and patching changes, backed by 24×7 emergency restoration.
How many patch cords do I need?
Two per outlet — one from the desk or device to the wall socket, one from the patch panel to the switch. Buy the lengths you actually need rather than one long size for everything, because coiled slack behind a rack is a common cause of a link failing certification later.
Can you quote against our BOQ?
Yes. Send the BOQ as it stands and we quote line by line against your model numbers, flag anything discontinued with an equivalent, and confirm what is in stock against what needs an indent. Project pricing is held for the duration rather than requoted per despatch.